Master Lock XR20 Wartungshandbuch Seite 77

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 129
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 76
This command sets the operational mode of the power supply: rotary, keypad, external, or remote.
Keypad configuration is not available for XR Series power supplies.
Command Syntax: [CONFigure]:SETPT <NR1>
Parameters: 0 = ROTARY, 1 = KEYPAD, 2 = EXTERNAL, 3 = REMOTE
Examples: CONF:SETPT 0
SETPT 0
Query Syntax: [CONFigure]:SETPT?
Returned Parameters: <NR1>
Related Commands: None
4.3.11 GPIB Communications Subsystem
4.3.11.1 GPIB:VERS? (Optional GPIB only)
This query reads the firmware version of the GPIB communication module.
Command Syntax: none
Query Syntax: [SYSTem][:COMMunicate]:GPIB:VERSion?
Parameters: none
Examples: SYST:COMM:GPIB:VERS?
GPIB:VERS?
Returned Parameters: <Firmware Ver. XX.Y>
Related Commands: None
4.3.11.2 GPIB:ADDR (Optional GPIB only)
This command sets the address of the GPIB module of the power supply. The address can be 1 to
30 where address 0 is normally assigned to the GPIB Master. The factory default address is 1.
Command Syntax: [SYSTem][:COMMunicate]:GPIB:ADDRess <NR1>
Parameters: 1-30
Examples: SYST:COMM:GPIB:ADDR 27
GPIB:ADDR 27