BIT ERROR CODE ERROR TYPE
5 100 through -199 Command
4 200 through -299 Execution
3 300 through -399 Device dependent
2 400 through -499 Query
Table 4.10 ERROR MESSAGES
ERROR ERROR STRING DESCRIPTION
-100 Command error generic command error
-102 Syntax error unrecognized command or data type
-108 Parameter not allowed too many parameters
-222 Data out of range e.g., outside the range of this device
-350 Queue overflow errors lost due to too many errors in queue
-400 Query error generic query error
4.7 Restricted Command Set
Commands and queries described in this Section 4.0 require the power supply to be configured
for remote operation. There are instances when the power supply may be configured for rotary or
external programming and certain SCPI command features may be desirable. As defined in Table
4.11, a reduced set of commands and queries are available to allow this mode of operation.
Table 4.11 REMOTE INTERFACE AVAILABILITY DURING ROTARY AND
EXTERNAL PROGRAMMING
SCPI COMMAND DESCRIPTION PANEL (note 1)
SUBSYSTEM COMMAND/QUERY EXAMPLE
XRC XR
CQCQ
Source VOLT and VOLT:TRIG
VOLT:PROT
CURR and CURR:TRIG
CURR:PROT
PER (not available with XR Series)
!
!
!
!
!
!
!
!
!
!
!
!
Measure MEAS:VOLT?
MEAS:CURR?
!
!
!
!
System SYST:VERS?
SYST:ERR?
!
!
!
!