Query Syntax: [SYSTem][:COMMunicate]:GPIB:ADDR?
Returned Parameters: <NR1>
Related Commands: None
4.3.12 Ethernet Communications Subsystem
4.3.12.1 NET:VERS? (Optional Ethernet only)
This query reads the firmware and hardware versions of the Ethernet communications module.
Command Syntax: none
Query Syntax: [SYSTem][:COMMunicate]:NETwork:VERSion?
Parameters: none
Examples: SYST:COMM:NET:VERS?
NET:VERS?
Returned Parameters: <Firmware Rev. XX.Y, Hardware Rev. XX.Y>
Related Commands: None
4.3.12.2 NET:MAC? (Optional Ethernet only)
This query returns the MAC address of the Ethernet module. MAC address consist of two
number groups: the first three bytes are known as the Organizationally Unique Identifier (OUI),
which is distributed by the IEEE, and the last three bytes are the device’s unique serial number.
The six bytes are separated by hyphens. The MAC address is unique to the instrument and cannot
be altered by the user.
Query Syntax: [SYSTem][:COMMunicate]:NETwork:MAC?
Parameters: None
Examples: SYST:COMM:NET:MAC?
NET:MAC?
Returned Parameters: <XX-XX-XX-YY-YY-YY>
Related Commands: NET:ADDR, NET:GATE, NET:SUBN, NET:PORT, NET:HOST,
NET:DHCP